Soft starter setting
Reference voltage adjustment
Reference voltage is the basic condition of the equipment is able to start or not. Reference voltage adjustment requires the electric motor rotates immediately after voltage applied and the load start up. If the motor does not rotate after voltage applied, we should increase the reference voltage setting value; if the motor start speed is too fast, then reduce the reference voltage setting value. Reference voltage adjustment should be repeated for several times until the load starts immediately after voltage applied. For example, a smoke blower has a 110kW motor in debugging process with soft starter, reference voltage adjusts to 75% rated voltage, the starting current is 500A, motor start up fast; reference voltage adjusts to 40% rated voltage, motor start up in slow speed, starting current rise from 200A to 600A smoothly, and current return back after motor start is completed, therefore, it's fully meet the soft-start requirements.
Starting time adjustment
Motor acceleration torque and starting time has direct relationship. Electronic soft starter can make the motor with voltage ramp start from initial voltage to full voltage at the set time (0.5 to 2408). Like it can reduce water impact if we extend the time of water pump flow from 0 to 100%, increase the pump speed variation time means increase the starting time which can be achieved by adjusting the starting time of the soft starter. Starting time should be adjusted according to the specific loads and repeated tests, in order to achieve smooth acceleration within starting time.
Soft stop
Soft starter allows the output voltage decreases gradually to achieve soft stop, in order to protect the equipment. Such as the impact of the water pump, when the pump stops suddenly, the water flow inertia in the pipe will raise the pipe and valves pressure suddenly and cause pipeline damaged. Soft stop to extend parking time will solve such the impact.
Reference voltage is the basic condition of the equipment is able to start or not. Reference voltage adjustment requires the electric motor rotates immediately after voltage applied and the load start up. If the motor does not rotate after voltage applied, we should increase the reference voltage setting value; if the motor start speed is too fast, then reduce the reference voltage setting value. Reference voltage adjustment should be repeated for several times until the load starts immediately after voltage applied. For example, a smoke blower has a 110kW motor in debugging process with soft starter, reference voltage adjusts to 75% rated voltage, the starting current is 500A, motor start up fast; reference voltage adjusts to 40% rated voltage, motor start up in slow speed, starting current rise from 200A to 600A smoothly, and current return back after motor start is completed, therefore, it's fully meet the soft-start requirements.
Starting time adjustment
Motor acceleration torque and starting time has direct relationship. Electronic soft starter can make the motor with voltage ramp start from initial voltage to full voltage at the set time (0.5 to 2408). Like it can reduce water impact if we extend the time of water pump flow from 0 to 100%, increase the pump speed variation time means increase the starting time which can be achieved by adjusting the starting time of the soft starter. Starting time should be adjusted according to the specific loads and repeated tests, in order to achieve smooth acceleration within starting time.
Soft stop
Soft starter allows the output voltage decreases gradually to achieve soft stop, in order to protect the equipment. Such as the impact of the water pump, when the pump stops suddenly, the water flow inertia in the pipe will raise the pipe and valves pressure suddenly and cause pipeline damaged. Soft stop to extend parking time will solve such the impact.